Issues caused by incorrect RPA configuration
The article lists a number of the most common issues stemming from incorrect RPA configuration and tips to troubleshoot them.
RPA recordings are not uploaded to S3
To resolve the problem, set /config/bot-agent/rpa.recording.enabled (in Work.AI v10.3, /config/bot-agent/rpa.upload.recording.s3), on the ZooKeeper node to true and restart the WorkFusion services.
Web automation fails with 'DriverCallTimeoutException' error
To avoid the Business Process failure, configure the following property in {RPA_INSTALLATION_FOLDER}/worker/worker.bat:
Drpa.timeouts.http=<value_in_milliseconds>
Desktop automation fails with 'NativeTimeoutException' error
To avoid the Business Process failure, configure the following property in {RPA_INSTALLATION_FOLDER}/worker/worker.bat:
Drpa.timeouts.mfw=<value_in_milliseconds>
Windows Defender blocks execution of D:/rpa/java/bin/java.exe
The following symptoms indicate the issue:
You see the Windows Defender screen appear during process execution.

In the Windows event logs, you see the following message:
A rule has been added to the Windows Defender Firewall exception list.
Added Rule:
Rule ID: TCP Query User{ADA6DD42-7CF4-4132-92DB-7AAA2F96F462}D:\rpa\java\bin\java.exe
Rule Name: Zulu Platform x64 Architecture
Origin: Local
Active: Yes
Direction: Inbound
Profiles: Public
Action: Block
Application Path: D:\rpa\java\bin\java.exe
Service Name:
Protocol: TCP
Security Options: None
Edge Traversal: None
Modifying User: S-1-5-80-3088073201-1464728630-1879813800-1107566885-823218052
Modifying Application: C:\Windows\System32\svchost.exe
To resolve the issue, add /rpa/java/bin/java.exe to the whitelist of Windows Firewall.
Out-of-memory error for Worker
To resolve any RPA issue due to the cause, change the Xms and Xmx Worker memory setting in worker.bat or bot-agent-unit.yml.
Worker closed during process execution by CTRL+C
To enable the Worker console to ignore the CTRL+C signal, set the associated variable to true. You can do this in bot-agent-unit.yml/worker.bat in the standard way through the -D switch. For example, insert the following line:
-Drpa.worker.ignore.ctrlc=true
Desktop automation fails due to Display Shutdown Event Tracker window
The desktop automation fails due to the Display Shutdown Event tracker window appearing in front of the application.
![]()
To resolve the issue, do as follows:
Open Control Panel > Windows Tools and select Edit group policy.

In the Local Group Policy Editor window, select Local Computer Policy > Computer Configuration > Administrative Templates > System.

Double-click Display Shutdown Event Tracker, set it to Disabled, and click OK.

View also: