RPA Server Upgrade
Upgrade under Windows
Back up the current installation. Copy RPA folder (
C:\RPA) toC:\RPA_old.Uninstall RPA using the respective item from Programs and Features in Control Panel.
Install RPA as described in RPA Server Installation.
If
hub.jsonandnodeX.jsoninC:\RPA\rpa-grid\have been modified in the previous installation for any particular purposes, replace the newly created files with those from the backup, for example,C:\RPA_old\rpa-grid\.
Upgrade under Linux
Run the following file to stop RPA Manager:
$INSTALL_DIR/apps/rpa-manager/stop.shReplace the RPA Manager file (
rpa-manager-server-$version.war) in the RPA Manager folder ($INSTALL_DIR/apps/rpa-manager/) with the new one.Run the following file to start RPA Manager:
$INSTALL_DIR/apps/rpa-manager/start.sh
RPA Package Selenium 3 Upgrade
Hub.json

Selenium 2
{
"host": null,
"port": 4444,
"newSessionWaitTimeout": 300000,
"servlets": ["com.workfusion.grid.web.WFServlet",
"com.workfusion.grid.web.HealthCheckHubServlet"],
"prioritizer": null,
"capabilityMatcher": "com.workfusion.grid.hub.ConfigurableCapabilityMatcher",
"capabilityMatcherConfig" : [{"platform":"platform"},
{"browserName":"exact"},
{"version":"rvm"}],
"throwOnCapabilityNotPresent": true,
"nodePolling": 5000,
"cleanUpCycle": 5000,
"timeout": 300000,
"browserTimeout": 0,
"maxSession": 30,
"jettyMaxThreads": -1
}
Selenium 3 (RPA 8.5.0)
{
"host": null,
"port": 4444,
"newSessionWaitTimeout": 300000,
"servlets": ["org.openqa.grid.selenium.workfusion.grid.web.WFServlet",
"org.openqa.grid.selenium.workfusion.grid.web.HealthCheckHubServlet"],
"prioritizer": null,
"capabilityMatcher": "org.openqa.grid.internal.utils.ConfigurableCapabilityMatcher",
"capabilityMatcherConfig" : [{"platform":"platform"},
{"browserName":"exact"},
{"version":"rvm"}],
"throwOnCapabilityNotPresent": true,
"nodePolling": 5000,
"cleanUpCycle": 5000,
"timeout": 300000,
"browserTimeout": 0,
"maxSession": 30,
"jettyMaxThreads": -1
}
NodeX.json

Selenium 2
{
"capabilities":[
{
"platform": "WINDOWS",
"browserName": "internet explorer",
"version": "11",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"platform": "WINDOWS",
"browserName": "desktop",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"platform": "WINDOWS",
"browserName": "universal",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"browserName": "chrome",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"browserName": "firefox",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
}
],
"configuration":{
"servlets": "com.workfusion.grid.web.HealthCheckNodeServlet",
"maxSession":2,
"port":5000,
"host": "127.0.0.1",
"register":true,
"registerCycle": 5000,
"hubPort":4444,
"hubHost":"127.0.0.1",
"nodeTimeout":120,
"nodePolling":2000,
"cleanUpCycle":2000,
"timeout":600000
}
}
Selenium 3 (RPA 8.5.0)
{
"capabilities":[
{
"platform": "WINDOWS",
"browserName": "internet explorer",
"version": "11",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"platform": "WINDOWS",
"browserName": "desktop",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"platform": "WINDOWS",
"browserName": "universal",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"browserName": "chrome",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
},
{
"browserName": "firefox",
"version": "1.0",
"maxInstances": 1,
"seleniumProtocol": "WebDriver"
}
],
"servlets": ["org.openqa.grid.selenium.workfusion.grid.web.HealthCheckNodeServlet"],
"maxSession":2,
"port":5000,
"host": "127.0.0.1",
"hubPort":4444,
"hubHost":"127.0.0.1",
"nodePolling":2000,
"cleanUpCycle":2000,
"timeout":600000
}
start-hub.bat

Selenium 2
...
:start
echo "%_messageStarting%"
cd /d %~dp0
%_javaPath%\bin\java -Dfile.encoding=UTF-8 %_logConfig% -cp %_javaPath%\lib\tools.jar;*;dependency\* com.workfusion.grid.CustomGridLauncher %_role% %_config%
:end
...
Selenium 3 (RPA 8.5.0)
...
:start
echo "%_messageStarting%"
cd /d %~dp0
%_javaPath%\bin\java -Dfile.encoding=UTF-8 %_logConfig% -cp %_javaPath%\lib\tools.jar;*;dependency\* org.openqa.grid.selenium.workfusion.grid.SeleniumGridLauncher %_role% %_config%
:end
...
start-nodeX.bat

Selenium 2
...
:start
echo "%_messageStarting%"
cd /d %~dp0
%_javaPath%\bin\java -Dfile.encoding=UTF-8 %_logConfig% -cp %_javaPath%\lib\tools.jar;*;dependency\* com.workfusion.grid.CustomGridLauncher %_role% %_config%
:end
...
Selenium 3 (RPA 8.5.0)
...
:start
echo "%_messageStarting%"
cd /d %~dp0
%_javaPath%\bin\java -Dfile.encoding=UTF-8 %_logConfig% -cp %_javaPath%\lib\tools.jar;*;dependency\* org.openqa.grid.selenium.workfusion.grid.SeleniumGridLauncher %_role% %_config%
:end
...
Application properties
The following new properties should be added to the application.properties file: